TM 5-3895-379-10
TROUBLESHOOTING PROCEDURES - CONTINUED
0010 00
Table 1. Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ENGINE - CONTINUED
2. Engine Starts But Will Not Keep Running -
3. Remove strainer and visually
a. If fuel tank is empty, fuel level
Continued.
inspect fuel in fuel tank.
gauge does not operate. Install
strainer and fill fuel tank with
supervisor that fuel level
gauge does not operate.
b. If fuel is contaminated, notify
supervisor.
c. If fuel tank contains clean fuel,
install strainer, fuel cap
assembly and padlock and go
to Step 4.
4. Open right- and/or left-side
a. Open fuel/water separator(s)
drain valve(s) and drain
b. If engine still does not keep
running, go to Step 5.
a. If air cleaner primary element
5. Open left-side door assembly
is clogged, clean by tapping
element with hand to remove
service indicator for red
dirt. Install secondary and
indication
on
viewing
primary filter elements and
window. Red indicates a
cover and close two air cleaner
clogged air cleaner primary or
housing latches. Reset air filter
secondary element. If filter
service indicator. Close left-
service indicator shows red in
viewing window, unlatch two
air cleaner housing latches and
remove
cover.
Remove
primary
and
secondary
elements from air cleaner
housing.
0010 00-8