TM 5-3895-383-24
The nominal amperage for the "P5" low amplitude-minimum
frequency potentiometer (6) is 450 mA.
Place the vibratory amplitude control (2) in the HIGH
AMPLITUDE position and turn the variable vibration control
knob (3) to a full counterclockwise position. The position
enables the "P6" potentiometer (8) to control the amperage to
the pump control. The position enables the "P6" potentiometer
(8) to maintain the lower limit of vibration per minute (VPM) at
1400 50 VPM.
The nominal amperage for the "P6" high amplitude-minimum
frequency potentiometer (8) is 450 mA.
Place the vibratory amplitude control (2) in the LOW
AMPLITUDE position and turn the variable vibration control
knob (3) to a full clockwise position. The position enables the
"P3" potentiometer (9) to control the amperage to the pump
control. The position enables the "P3" potentiometer (9) to
maintain the upper limit of vibration per minute (VPM) for the
CP-563D and the CS-563D at 1965 50 VPM. The upper limit
of vibration per minute (VPM) for the CS-583D is 1800 50
VPM.
The nominal amperage for the "P3" low amplitude-maximum
frequency potentiometer (9) is 520 mA.
Place the vibratory amplitude control (2) in the HIGH
AMPLITUDE position and turn the variable vibration control
knob (3) to a full clockwise position. The position enables the
"P4" potentiometer (10) to control the amperage to the pump
control. The position enables the "P4" potentiometer (10) to
maintain the upper limit of vibration per minute (VPM) for the
CP-563D and the CS-563D at 1965 50 VPM. The upper limit
of vibration per minute (VPM) for the CS-583D is 1800 50
VPM.
The nominal amperage for the "P4" high amplitude-maximum
frequency potentiometer (10) is 520 mA.
11-31