TM 5-3895-382-24
Avoid prolonged skin contact with Isopropyl alcohol.
Avoid breathing the vapors in enclosed areas without
adequate ventilation and do not smoke. Do not use near
open flame or welding operations or other heated surfaces
exceeding 482° C (900° F).
2.
Put toric ring (2) on seal ring (1), at the bottom of seal
ramp (7) and against retaining lip (8).
NOTICE
Make sure that toric ring (2) is straight on seal ring (1) and
not twisted. Be careful when you work on the rubber toric
ring. Nicks, cuts and scratches can cause leaks.
3.
Put installation tool (9) onto seal ring (1) with toric ring
(2). Lower the rings into a container with Isopropyl
alcohol until all surfaces of toric ring (2) are wet.
NOTICE
Do not use Stanisol or any other liquid that leaves an oil
film or does not evaporate quickly.
4.
With all surfaces of toric ring (2) wet, use installation tool
(9) to position seal ring (1) and toric ring (2) squarely
against housing (5) as shown. Use sudden and even
pressure to pop (push) toric ring (2) under retaining lip
(3) of housing (5).
16-5