VIBRATORY MOTOR REPLACEMENT - CONTINUED
0206 00
REMOVAL
1.
Remove cable tie (1) and disconnect electrical connector (2).
1
9
2
3
4
3
2
6,7
8
401-2149
5
4
CAUTION
Cap and plug all hoses, fittings and openings immediately after removal. Contaminants entering the system
may cause premature failure.
NOTE
Use container to catch any hydraulic oil that may drain from system. Dispose of oil IAW local policy
and ordinances. Ensure all spills are cleaned up.
Tag and mark all hydraulic lines and hoses to ensure correct installation.
2.
Disconnect two hose assemblies (3) and two hose assemblies (4) from vibratory motor (5).
3.
Remove four nuts (6) and washers (7) from plate (8).
0206 00-2