TM 5-3895-379-23
DRAIN COCK AND TEE REPLACEMENT - CONTINUED - CONTINUED
0157 00
REMOVAL - CONTINUED
NOTE
Note location and position of each fitting
13
to aid in installation.
7
17
5.
Remove drain cock (18), adapter (7) and two elbows
12
(12) and (13) from tee (17).
18
401-782
CLEANING AND INSPECTION
1.
Clean tee, fittings and drain cock with detergent and water. Remove difficult deposits with cleaning brush.
WARNING
Particles blow by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when cleaning components.
DO NOT direct compressed air against human skin. Failure to follow this warning may cause injury or
death. Make sure air stream is directed away from user and other personnel in the area. To prevent
injury, user must wear protective goggles or face shield.
2.
Use a cleaning cloth or compressed air to dry metal parts.
3.
Check tee for clogging, corrosion or excessive wear.
4.
Check drain cock for clogging, corrosion, excessive wear and obvious signs of damage.
5.
Check all parts for stripped or damaged threads.
6.
Replace all damaged parts.
INSTALLATION
1.
Apply sealing compound to threads and install drain cock (18), adapter (7) and two elbows (12) and (13) in tee (17).
0157 00-3