TM 5-3895-379-23
MANUAL BRAKE RELEASE PUMP MAINTENANCE - CONTINUED
0117 00
REMOVAL
CAUTION
Cap all hoses and fittings to prevent contamination that can cause damage to equipment.
NOTE
Tag and mark all hoses prior to removal.
Inspect all hoses, lines and fittings for cracks, bends, nicks, dents, stripped threads and cuts. Replace all
damaged parts.
Use container to catch any hydraulic oil that may drain from system. Dispose of oil IAW local policy
and ordinances. Ensure all spills are cleaned up.
1.
Remove hose (1) and O-ring (2) from elbow (3). Dis-
card O-ring.
2.
Remove hose (4) and O-ring (5) from elbow (6). Dis-
card O-ring.
2
1
3
4
5
6
401-619
0117 00-2