TM 5-3895-379-23
WATER TEMPERATURE SENDING UNIT REPLACEMENT - CONTINUED
0095 00
REMOVAL
1.
Disconnect connector (1) from water temperature sending unit connector (2).
NOTE
Use container to catch any coolant that
may drain from water temperature sending
unit. Dispose of coolant IAW local policy
and ordinances. Ensure all spills are
cleaned up.
2.
Place container with 1 gal. (3.8 l) minimum capacity
under water temperature sending unit (3) to catch
draining coolant.
NOTE
Remove cable ties as required.
3.
Remove water temperature sending unit (3) from
water intake manifold (4).
INSTALLATION
1.
Coat threads of water temperature sending unit (3)
1
4
2
with sealing compound.
2.
Install water temperature sending unit (3) in water
3
intake manifold (4). Tighten water temperature send-
ing unit 32-44 lb-ft (44-60 Nm).
3.
Connect connector (1) to water temperature sending
unit connector (2).
401-505
4.
5.
Close right-side door assembly (TM 5-3895-379-10).
6.
Start engine and check for coolant leaks (TM 5-3895-379-10).
7.
Remove chocks (TM 5-3895-379-10).
END OF WORK PACKAGE
0095 00-2