TM 5-3895-379-23
VIBRATION PUSH SWITCH REPLACEMENT - CONTINUED
0080 00
REMOVAL - CONTINUED
NOTE
2
6
Nuts are small and easily lost. Take
1
8
extra care to not lose nuts.
Nuts may stay with grip housing.
9
3.
Remove two screws (6), four screws (7) and six nuts
11
(8) from grip housings (3 and 4).
4.
Remove two grip housing (3 and 4) from handle
12
pipe (5) and vibration push switch (9).
5.
Remove two gaskets (10) from grip housing (4).
10
10
Discard gaskets.
6.
Remove two screws (11) and wires (12) from vibra-
13
tion push switch (9).
7.
Remove nut (13) and preformed packing (14) from
4
handle pipe (5). Discard preformed packing.
7
14
8
5
3
401-475
INSTALLATION
1.
Install new preformed packing (14) and nut (13) on handle pipe (5). Turn nut onto handle pipe until top of nut is
flush with top of handle pipe.
2.
Install two wires (12) on vibration push switch (9) with two screws (11).
3.
Install two new gaskets (10) in grip housing (4).
NOTE
Grip housings will not fit together if any threads of handle pipe are showing on top side of nut while
nut is installed.
Mate flat sides of nut with cavity on grip housing.
4.
Install grip housing (4) on handle pipe (5), nut (13) and new preformed packing (14).
5.
Install vibration push switch (9) in grip housing (4).
6.
Install grip housing (3) on grip housing (4) with two screws (6), four screws (7) and six nuts (8).
7.
Tighten grip housings (3) and (4) on handle pipe (5) by turning grip housings to right until snug. Do not over-
tighten.
0080 00-2