TM 5-3895-379-23
FUEL CAP ASSEMBLY MAINTENANCE - CONTINUED
0039 00
CLEANING AND INSPECTION
WARNING
Cleaning compound, solvent MIL-PRF-680 Type III is an environmentally compliant and low toxic
material. However, it may be irritating to the eyes and skin. The use of protective gloves and goggles is
suggested. Use in well-ventilated areas. Keep away from open flames and other sources of ignition.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when cleaning compo-
nents. DO NOT direct compressed air against human skin. Failure to follow this warning may cause
injury or death. Make sure air stream is directed away from user and other personnel in the area. To pre-
vent injury, user must wear protective goggles or face shield.
1.
Clean all metal parts with cleaning compound, solvent.
2.
Use cleaning cloth or compressed air to dry all metal parts.
3.
Check cap for nicks, cracks, dents and stripped threads. Replace any damaged parts.
ASSEMBLY
1.
Install filter element (9) and filter (10) in fuel cap assembly (2).
2.
Install new gasket (8), baffle (7), washer (6) and valve assembly (5) in fuel cap assembly (2). Tighten valve assembly
securely.
3.
Install new gasket (4) in fuel cap assembly (2).
INSTALLATION
1.
Install fuel cap assembly (2) on fuel tank (3) by turning fuel cap assembly clockwise.
2.
Install lock (1) in eye of fuel cap assembly (2), one eye left of lock stop.
3.
Remove chocks (TM 5-3895-379-10).
END OF WORK PACKAGE
0039 00-3/(0039 00-4 Blank)