TM 5-3895-379-23
FUEL/HYDRAULIC OIL TANK AND DRAIN LINES REPLACEMENT - CONTINUED
0038 00
CLEANING AND INSPECTION
WARNING
Cleaning compound, solvent MIL-PRF-680 Type III is an environmentally compliant and low toxic
material. However, it may be irritating to the eyes and skin. The use of protective gloves and goggles is
suggested. Use in well-ventilated areas. Keep away from open flames and other sources of ignition.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when cleaning compo-
nents. DO NOT direct compressed air against human skin. Failure to follow this warning may cause
injury or death. Make sure air stream is directed away from user and other personnel in the area. To pre-
vent injury, user must wear protective goggles or face shield.
1.
Clean all metal parts with cleaning compound, solvent.
2.
Dry all parts with compressed air.
3.
Inspect tank for rust, cracks, dents and holes.
4.
Inspect strainers for holes, tears and debris.
5.
Inspect all fittings and connectors for stripped threads.
6.
Repair or replace all damaged parts.
TANK INSTALLATION
1.
Apply sealing compound to threads of two connectors
73
(74) and install connectors and new O-rings (39) on
fuel/hydraulic oil tank (32). Install two rubber sheets
73
(73) on fuel/hydraulic oil tank with gasket cement.
2.
Install six rubber sheets (72) on fuel/hydraulic oil tank
(32) using gasket cement.
32
74
39
401-358
0038 00-14