Figure 2. Electrical General Maintenance Instructions.
Figure 4. Electrical General Maintenance Instructions.

Technical Manual For Roller, Motorized, Vibrating Tandem Steel Drums - 2 Page Navigation
  349    350    351    352    353  354  355    356    357    358    359  
img
.
TM 5-3895-379-23-2
0280
MULTIMETER USAGE - Continued
(c)
Multimeter "C" is used to measure voltage drop across a load, in this case a lamp. If voltages
at multimeters "A" and "B" are 0.1 volt each, voltage reading at multimeter "C" will equal 23.8
volts. This is because the sum of all voltage drops in a circuit is equal to the source voltage.
24 - VOLT
BATTERY PACK
GOOD SPLICE
CONNECTION
LAMP
SWITCH
(CLOSED)
M0279SWR
C
Figure 3. Electrical General Maintenance Instructions.
0280-5