TM 5-3895-379-23-2
0259
INSTALLATION
CAUTION
Wipe all ends, line fittings, and mounting surfaces clean and dry.
Utilize line wrenches for installation to avoid damage to fittings and connectors.
NOTE
Apply a light film of clean lubricating oil to all new O-rings prior to installation.
1.
Install new gasket (Figure 2, Item 13) and new O-ring (Figure 2, Item 11) on check valve (Figure 2, Item 12).
Install check valve.
2.
Install elbow boss fitting (Figure 2, Item 2) on check valve (Figure 2, Item 12).
3.
For hydraulic lines with elbow bosses, connect line (Figure 2, Item 1) to elbow boss fitting (Figure 2, Item 2).
4.
For hydraulic lines with elbow fittings, install two new O-rings (Figure 2, Items 8 and 9) on elbow fitting
(Figure 2, Item 10). Install elbow fitting.
5.
Install end of line (Figure 2, Item 14) on elbow fitting (Figure 2, Item 10).
6.
For lines held in position with clamp, install clamp (Figure 2, Item 5), washer (Figure 2, Item 4), bolt
(Figure 2, Item 3), washer (Figure 2, Item 6), and nut (Figure 2, Item 7) on line or lines.
0259-4
03/15/2011Rel(1.8)root(maintwp)wpno(M00197)