TM 5-3895-379-23-1
0219
CLEANING AND INSPECTION
WARNING
Cleaning compound, solvent MIL-PRF-680 Type III is an environmentally compliant and
low toxic material. However, it may be irritating to the eyes and skin. The use of protective
gloves and goggles is suggested. Use in well-ventilated areas. Keep away from open
flames and other sources of ignition.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa)
nozzle pressure when drying parts with compressed air. Use a maximum of 30 psi
(207 kPa) when cleaning components. DO NOT direct compressed air against human
skin. Failure to follow this warning may cause injury or death. Make sure air stream is
directed away from user and other personnel in the area. To prevent injury, user must
wear protective goggles or face shield.
1.
Clean all metal parts with cleaning compound, solvent.
2.
Thoroughly clean O-ring grooves in valve body.
3.
Use compressed air to dry valve body.
4.
Check bores for scratches or damage.
5.
Check valve body for cracks or damage.
6.
Check all threads for peeled or crossed condition.
7.
Inspect hand pump (CB534B) for cracks, nicks, or stripped threads.
8.
Replace all damaged parts.
END OF TASK
0219-6
03/15/2011Rel(1.8)root(maintwp)wpno(M00157)