REMOVAL
WARNING
If NBC exposure is suspected, personnel wearing protective equipment should handle
all air cleaner media. Consult your NBC Officer or NBC NCO for appropriate handling or
disposal procedures.
NBC contaminated filters must be handled using adequate precautions (FM 21-40) and
must be disposed of by trained personnel.
1.
Release two latches (Figure 1, Item 3) and remove cover (Figure 1, Item 7) from air cleaner body assembly
(Figure 1, Item 4).
2.
Remove primary air cleaner element (Figure 1, Item 6) from air cleaner body assembly (Figure 1, Item 4).
3.
Remove secondary air cleaner element (Figure 1, Item 5) from air cleaner body assembly (Figure 1, Item 4).
4.
Loosen clamp (Figure 1, Item 1) and remove cap (Figure 1, Item 2) from air cleaner body assembly
(Figure 1, Item 4).
2
1
5
7
6
3
4
M0475SWR
Figure 1.
Air Cleaner Elements and Air Cleaner Assembly Removal.
5.
Remove tube (Figure 2, Item 4) from tube connector (Figure 2, Item 5).
6.
Loosen clamp (Figure 2, Item 2) and remove hose (Figure 2, Item 1) from air cleaner body assembly
(Figure 2, Item 3).