TM 5-3895-379-10
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0012 00
Table 1. Operator Preventive Maintenance Checks and Services (PMCS) for DSWR - Continued.
LOCATION
ITEM TO
ITEM
MAN-
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
HOURS
SERVICE
PROCEDURE
CAPABLE IF:
16
Before
V-Belts
(Con't)
CRACKED/SPLIT
GREASY
GLAZED
PEELING
401-022
17
Before
Water Pump
Check for coolant leakage at radiator
hoses and water pump.
a. A small amount of coolant leakage Class III coolant leaks are
across the surface of the water pump evident.
seals is normal. This leakage is
required in order to provide lubrica-
tion for this type of seal.
b. A hole is provided in the water pump
housing in order to allow this cool-
ant/seal lubricant to drain from the
pump housing.
c. Intermittent leakage of small
amounts of coolant from this hole
indicates normal operation. It is not
an indication of water pump seal
failure or a faulty water pump.
0012 00-7