TM 5-3895-379-10
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0012 00
Table 1. Operator Preventive Maintenance Checks and Services (PMCS) for DSWR - Continued.
LOCATION
ITEM TO
ITEM
MAN-
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
HOURS
SERVICE
PROCEDURE
CAPABLE IF:
6
Before
Air Filter
(Con't)
Service Indi-
cator
FUEL/WATER SEPARATOR
CLOSED
OPEN
401-020
WARNING
DO NOT perform fuel/water separator checks, inspections or
draining while smoking, or when near fire or sparks. Fuel may
ignite, causing injury, death or damage to roller.
CAUTION
Operation of roller with damaged fuel/water separator can cause
engine damage.
a. Check fuel/water separator for leaks Any leakage from fuel/water
7
Before
0.1 Hours Fuel/Water
or damage such as cracks.
separator is evident that fuel/
Separator
water separator is damaged.
(Primary)
b. Place container with minimum 1 qt
(1 l) capacity under fuel/water sepa-
rator.
c. Open drain valve and drain fluid
until only fuel comes out. Close
drain valve.
d. Dispose of drained fluids in accor-
dance with local regulations.
0012 00-3