TM 5-3895-346-14
REPAIR
HYDROSTATIC SYSTEM
REPLACEMENT OF MOTOR OR PUMP SHAFT SEAL
REMOVAL
1.
Remove unit from installation.
2.
Insert Truarc #7 pliers in snap- ring holes, compress ring and roll out (refer to Fig. 16).
3.
Remove aluminum seal retainer with screwdriver (refer to Fig. 17).
4.
Remove steel stationary seal (this generally comes out with retainer) (refer to Fig. 18).
Figure 16.
Figure 17.
5. With fingers or two screwdrivers remove bronze rotating part of seal from drive shaft (refer to Fig. 20).
6. Refer to Fig. 19 and account for all the parts shown.
Figure 18.
Figure 19.
Figure 20.
508