1
Magneto frame
10
Primary ground spring
2
Coil lead
11
Breaker spring
3
Distributor gear
12
Breaker plate
4
Ventilator hood
13
Felt
5
Distributor rotor
14
Breaker cam
6
Condenser
15
Lock pin
7
Condenser mounting screw
16
Breaker points
8
Condenser lead
17
Coil
9
Screw, locking
Figure 35. Magneto.
(1) Unscrew the breaker arm terminal screw and disconnect the coil lead (2) and condenser lead (8) from the
terminal.
(2) Remove the lock pin (15) and lift up the breaker arm from the stud.
(3) Remove the screws (9) and breaker plate.
(4) Install a new breaker plate (12) and tighten the screws (9).
(5) Install the breaker arm on the stud and secure it with the lock pin (15).
(6) Connect the breaker arm spring ( 11), condenser lead (8), and coil lead (2) with the breaker arm terminal.
Tighten the screw.
(7) Adjust the breaker points (e above).
(1) Disconnect the condenser lead (8) from the breaker arm terminal.
103