Voltage Regulator
Figure 30. Starting motor, sectional view.

Roller, Road, Gasoline Driven, Tandem, 2 Axle, 5 To 8 Ton, Galion Model T5G W/Engine Continental Model F-244
Page Navigation
  88    89    90    91    92  93  94    95    96    97    98  
img
.
1
Generator pulley
8
Oil filler cap
2
Generator
9
Mounting nut
3
Mounting screw
10
Mounting washer
4
Voltage regulator cover screw
11
Radio suppression capacitor
5
Voltage regulator
12
Lead mounting screw
6
Shielded leads
13
Crankshaft pulley
7
Cylinder block
14
Mounting rubber washer
Figure 29. Voltage regulator removal points.
114. Starting Motor
a. Description (fig. 30). The starting motor converts electrical energy from the battery into mechanical power and
transmits this power to the engine. It consists of the end bracket (16), armature (13), frame and field coils (12), drive
housing (7), and drive assembly (6, 8, 10, and 11), located inside the drive housing. The drive pinion (11) is mounted on
the screw shaft (8) which is driven by a spring (6) connected with the armature shaft (5) and the drive shaft (8). When the
starting motor circuit is closed, the armature (13) revolves and turns the screw shaft (8) within the pinion (11). This screw
action forces the pinion (11) forward into mesh with the flywheel gear. The sudden shock of meshing is absorbed by the
drive spring (6). When