TM 5-3895-379-23-1
0206
REMOVAL - Continued
3.
Loosen hydraulic oil tank fill cap (Figure 2, Item 1) to release hydraulic pressure.
NOTE
Tag and mark all lines and wires to ensure correct installation.
Cap and plug all lines and fittings to prevent any contaminants from entering the system.
Use drain pan to catch any oil that may drain from system. Dispose of oil IAW local policy
and ordinances. Ensure all spills are cleaned up.
4.
Remove four hose assemblies (Figure 2, Item 10) from propel control valve (Figure 2, Item 5).
5.
Disconnect electrical connector (Figure 2, Item 8).
6.
Remove two wires (Figure 2, Item 7) from backup alarm switch (Figure 2, Item 9).
7.
Remove four bolts (Figure 2, Item 2) and nuts (Figure 2, Item 3) from plate assembly (Figure 2, Item 6).
8.
Remove propel control valve (Figure 2, Item 5) and lever assembly (Figure 2, Item 4) as a unit from plate
assembly (Figure 2, Item 6).
1
2, 3
4
5
6
10
9
8
7
M0361SWR
Figure 2.
Propel Control Lever Removal.
END OF TASK
03/15/2011Rel(1.8)root(maintwp)wpno(M00144)