TM 5-3895-383-24
(3)
Torque for plug .........................................50 Nm (37 lb-ft)
(4)
Torque for four bolts ................................48 Nm (35 lb-ft)
(5)
Torque for plug ...................135 ± 15 N m (100 + 11 lb-ft)
(6)
The maximum displacement position .................14.5 mm
................................................................................ (0.57 inch)
(7)
Torque for plug ............................40 ± 5 N m (30 ± 4 lb-ft)
(8)
Torque for plug ............................40 ± 5 Nm (30 ± 4 lb-ft)
(9)
Torque for plug ............................40 ±·5 N m (30 ± 4 lb-ft)
Case drain with the flushing valve ...................................10 L/min
(2.6 US gpm)
Case drain without the flushing valve .....................................3.8 L
(1 US gal)
(10)
Diameter of the orifice in the flushing
valve............................................................ 2 mm (0.08 inch)
Relief pressure .................................................1800 kPa (261 psi)
10-17