TM 5-3895-383-24
Typical Example
3E6451
With a decrease in temperature, the switch must close
at a minimum of ..........................................................93°C (200°F)
With an increase in temperature, the switch must
open ............................................................ 107 ± 3°C (225 ± 37°F)
When installing torque to .......................61 ± 7 N m (45 ± 5 Ib-ft)
3E6449
With a decrease in temperature, the switch must close
at a minimum of .........................................................27°C (80.6°F)
With an increase in temperature, the switch must
open at.......................................................38 ± 3°C (100 ± 37.4°F)
When installing torque to .......................61 ± 7 N m (45 ± 5 Ib-ft)
(1) Tighten to a torque of........20 ± 3 N m (15 ± 2 lb-ft)
Aftercooler Group
Right Side View
(1) Aftercooler.
(2) Bolt. Used for inlet manifold cover or aftercooler
NOTE: Apply 5P3431 Pipe Sealant to bolt threads marked
"Y".
(3)
Nipple. Remove the plug and seal before installing nipple.
7-8