TM 5-3895-383-24
When installing the switch, tighten to a
torque of ................................................ 35 ± 3 N m (26 ± 2.2 Ib-ft)
Terminal A is common.
Terminal B is normally open.
Terminal C is normally closed.
6T6651
With a pressure increase, terminal B closes and
terminal C opens at .................................90 ± 21 kPa (13 ± 3 psi)
With a pressure decrease, terminal B opens and
terminal C closes at ................................70 ± 21 kPa (10 ± 3 psi)
With a decrease in pressure, the switch must close at a
minimum of ...............................................70 ± 20 kPa (10 ± 3 psi)
With an increase in pressure, the switch must open at
a maximum of ......................................................... 70 kPa (10 psi)
When installing torque to .......................35 ± 3 N m (26 ± 2 lb-ft)
Transmission Oil Temperature Switch
With a decrease in temperature the switch must close
at a minimum of..................................................... 93.33°C (200°F)
With an increase in pressure, the switch must
open at ............................................101.67 ± 2.78°C (215 ± 37°F)
(1) Body. Torque to a maximum of .................68 Nm (50 lb-ft)
(2) Bolt. Torque to a maximum of................. 1.2 Nm (11 Ib-in)