TM 5-3895-383-24
Use a torque wrench for proper installation of the constant
torque hose clamps. The constant torque hose clamp is
installed correctly under the following conditions:
Screw tip (1) extends 6.35 mm (.250 inch) (X) beyond
the housing.
The belleville washers are collapsed nearly flat after
screw (2) is tightened to a torque of 11 ± 1 Nm (98 ± 9
lb-in).
Torques for Ground Engaging Tool Bolts
SMCS Code: 6800; 7000; 7553
Table 12
Recommended Torque (1)
Bolt Size
N· m
lb-ft
5/8 inch
270 ± 40
200 30
3/4 inch
475 60
350 45
7/8 inch
750 90
550 65
1 inch
1150 ± 150
850 ± 110
1-1/4 inch
2300 300
1700 220
(1) These values are only for Caterpillar bolt for cutting edge.