TM 5-3895-382-24
Table 1-1. Unit Preventive Maintenance Checks and Services - CONT
Location
Item
Interval
Man-
Item to be
Procedure
Not Fully Mission
No.
hour
Checked or
Capable If:
Serviced
16
250 H
0.1
Batteries
a.
Inspect/service batteries (page 1-76). Check
Batteries are
or Q
battery cables for wear or damage
cracked,
(page 1-76) and (TM 9-6140-200-14).
connectors or
cables are worn
b.
Clean battery box. Repaint battery box
or damaged.
where paint is missing.
17
250 H
0.5
Fuel System
a.
Replace fuel/water separator element
or Q
(page 1-78).
b.
Replace fuel filter element (page 1-77).
c.
Clean fuel lift pump strainer and sediment
chamber (page 1-77).
d.
Clean fuel tank cap and fill screen strainer
(page 1-80).
18
250 H
0.1
Hydraulic
Clean hydraulic tank breather (page 1-81).
or Q
Tank
19
500 H
0.1
Cooling
Check coolant concentration. Add coolant if
or S
System
concentration ratio is incorrect (page 1-24).
20
500 H
0.1
Blade Cutting
a.
Inspect blade cutting edge for loose or
Cutting edge has
or S
Edge
missing bolts.
loose or missing
bolts.
b.
Inspect cutting edge for damage such as
cracks or tears (page 1-49).
c.
Inspect that cutting edges are not worn
Edge is worn
beyond 1/8 in. from blade (page 1-49).
beyond 1/8 in.
from blade.
1-16