TM 5-3895-379-23
INSTRUMENT WIRING HARNESS REPLACEMENT - CONTINUED
0112 00
REMOVAL
1.
Remove two shoulder screws (1), washers (2) and vandal guard (3) from instrument box assembly (4).
2.
Remove three screws (5) and washers (6) from operator station (7).
3.
Lift and tilt back instrument box assembly (4) to gain access to back of instrument box assembly.
3
2
1
7
6
5
4
401-601
4.
Remove four screws (8), washers (9), and cover (10)
10
from operator station (7).
9
8
7
401-602
0112 00-2