TM 5-3895-379-23
VIBRATIONS PER MINUTE (VPM) TACHOMETER AND FEET PER MINUTE (FPM)
METER REPLACEMENT - CONTINUED
0083 00
REMOVAL - CONTINUED
NOTE
16
20
Tag and mark all wires prior to removal.
17
24
9.
Remove nut (16), wire (17) and lockwasher (18) from
18
VPM tachometer terminal S (19). Discard lockwasher.
19
10.
Remove nut (20), wire (21) and lockwasher (22) from
21
VPM tachometer terminal I (23). Discard lockwasher.
11.
Remove nut (24), wire (25) and lockwasher (26) from
25
22
VPM tachometer terminal G (27). Discard lockwasher.
12.
26
23
assembly (4).
27
4
9
401-484
NOTE
Perform steps 13 through 22 for the CB534C Roller.
13.
Pull light fixture (28) and remove light fixture from FPM meter (29).
14.
Remove retainer clip (30) from light fixture (28).
15.
Push and twist light bulb (31) counterclockwise and remove light.
16.
If damaged, cut wire (32) and install new light fixture (28) using general wiring repair (WP 0108 00).
17.
Remove two nuts (33), lockwashers (34) and FPM meter bracket (35) from FPM meter studs (36). Discard lockwashers.
34
35
33
36
32
28
30
31
401-2223
0083 00-4