TM 5-3895-379-23
RELAY REPLACEMENT - CONTINUED
0068 00
REMOVAL - CONTINUED
4.
Remove connector (6) from relay (7).
NOTE
There are two methods of removing the relays. Perform step 5 or step 6 as the relay requires.
5.
Remove screw (8), washer (9) and relay (7) from panel assembly (5).
6.
Remove locknut (10), washer (11) and relay (7) from operator station (3). Discard locknut.
5
10
9
11
7
8
6
6
7
3
VIEW FROM DRIVER'S SEAT
401--452
401452
INSTALLATION
NOTE
There are two methods of installing relays. Perform step 1 or step 2 as relay requires.
1.
Install relay (7) on operator station (3) with washer (11) and new locknut (10).
2.
Install relay (7) on panel assembly (5) with washer (9) and screw (8).
3.
Install connector (6) on relay (7).
0068 00-4