TM 5-3895-379-23
ALTERNATOR CIRCUIT BREAKER REPLACEMENT - CONTINUED
0064 00
INSTALLATION
1.
Install circuit breaker (6) on air cleaner support assembly (9) with two new lockwashers (8) and screws (7).
2.
Install two terminals (2) and terminal (3) on circuit breaker assembly (6) with two new lockwashers (5) and screws (4).
Tighten screws to 2-4 lb-ft (3-5 Nm).
3.
Position cable boots (1) to cover two terminals (2) and terminal (3).
9
7
6
8
3
2
5
1
4
VIEW FROM BACK SIDE
401-434
4.
Close left-side door assembly (TM 5-3895-379-10).
5.
Remove chocks (TM 5-3895-379-10).
END OF WORK PACKAGE