TM 5-3895-379-23
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 1. Engine Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
10. Engine is Unusually Noisy.
system for loose or damaged
loose, tighten loose components.
components.
Damage
may
include holes rusted through 2. If muffler or exhaust is damaged,
replace damaged components
muffler or pipes, torn muffler or
pipes, or bent muffler or pipes.
3. If muffler and exhaust system are
not loose or damaged, go to Step 2.
WARNING
Use caution while working under operator platform assembly. Fall-
ing platform may cause injury or death.
2. Raise operator platform (WP 1. If fan assembly and guard are
loose or damaged, tighten or
and guard for looseness or
replace loose or damaged parts
damage such as cracked or
missing fan blade(s), loose nuts
and screws, bent or cracked fan
pulley, or damage or wear from 2. If fan assembly and guard are not
loose or damaged, go to Step 3.
extreme fan blade wobble.
FAN DRIVE
FAN V-BELTS
HOUSING
ASSEMBLY
FAN BLADE
FAN PULLEY
401-184