TM 5-3895-379-23-2
0281
STORAGE INSTRUCTIONS - Continued
k.
Prepare water spray system:
(1)
Remove water line at bottom of tanks and drain all water (TM 5-3895-379-10).
WARNING
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi
(103 kPa) nozzle pressure when drying parts with compressed air. Use a maximum
of 30 psi (207 kPa) when cleaning components. DO NOT direct compressed air
against human skin. Failure to follow this warning may cause injury or death. Make
sure air stream is directed away from user and other personnel in the area. To
prevent injury, user must wear protective goggles or face shield.
(2)
Disconnect water supply lines at water pumps (WP 0270) and blow lines out with low pressure air
(30 psi or less).
(3)
With lines still disconnected from pumps turn water pumps on for a short time to purge water from
pumps.
(4)
Remove water strainers, drain, and install (WP 0271).
(5)
Connect water supply lines to water pumps (WP 0270).
(6)
Connect water line to bottom of tanks (TM 5-3895-379-10).
CAUTION
To prevent damage to alternator ensure that plug-in lead to alternator is disconnected.
l.
Disconnect plug-in lead to alternator (Volume 1, WP 0151) and tape.
CAUTION
Discharged batteries will be damaged if stored in below freezing temperatures.
m.
Remove batteries (Volume 1, WP 0191) and tape battery cable ends. Store batteries where they can be
checked periodically and recharged.
n.
Cover seat with barrier material.
o.
Tag roller as "STORED LONG TERM". List all work done on roller on the tag.
p.
Check roller every 45 to 60 days for signs of damage or deterioration. Repeat procedures if damage is
detected.
0281-4