TM 5-3895-379-10
TROUBLESHOOTING PROCEDURES - CONTINUED
0010 00
Table 1. Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ENGINE - CONTINUED
2. Engine Starts But Will Not Keep Running -
b. If air cleaner primary element
Continued.
is torn or ripped, notify
supervisor for replacement.
Install secondary and primary
filter elements and cover and
close two air cleaner housing
latches. Reset air filter service
indicator. Close left-side door
c. If air cleaner secondary
element is clogged, notify
supervisor for replacement.
Install secondary and primary
filter elements and cover and
close two air cleaner housing
latches. Reset air filter service
indicator. Close left-side door
d. If air cleaner elements are not
clogged and fault is not
corrected,
install
filter
elements and cover and close
two air cleaner housing
latches. Close left-side door
Notify supervisor.
SECONDARY
AIR FILTER SERVICE
HOUSING
ELEMENT
INDICATOR
SERVICE
SERVICE
PRIMARY
WHEN
WHEN
ELEMENT
RED
LEVEL IS
AT 22
VIEWING
WINDOW
HOUSING LATCHES
HOUSING COVER
401-084
0010 00-9