DETROIT DIESEL
Storage
outlined in Hydraulic Starting System. Then,
e. Refill the converter with the oil that is recommen-
drain, refill and purge the Hydrostarter system.
ded
under
and
Preventive
Lubrication
Maintenance.
15. TURBOCHARGER
13. POWER TAKE-OFF
Remove the covers from the turbocharger air inlet and
turbine outlet connections. Refer to the lubricating
Remove the inspection hole cover and inspect the
procedure outlined in Preparation for Starting Engine
clutch release lever and link pins and the bearing ends
First Time.
of the clutch release shaft. Apply engine oil sparingly,
if necessary, to these areas.
16. After all of the preparations have been completed,
start the engine. The small amount of rust preventive
14. HYDROSTARTER
compound which remains in the fuel system will cause
a. Open the relief valve on the side of the hand
pump and release the pressure in the system.
NOTE: Before subjecting the engine to a load or
high speed, it is advisable to check the engine
tune-up.
b. Refer to the filling and purging procedures
Page 122