(11) Remove the screw (27) and lockwasher (26) attaching the condenser and coil leads to the breaker arm (23).
Disconnect the leads from the breaker arm (23) and lift out the condenser (28) from the magneto frame.
(12) Remove the stationary support bracket locking screws (5 and 32), lockwashers (19 and 14), and plate
washers (20 and 31).
(13) Spread and remove the snap ring (22).
(14) Lift out and remove the stationary support bracket (21), breaker arm (23), cam wick (30), and primary
ground spring (24) from the magneto frame.
(15) Spread and remove the distributor shaft snap ring (10) and distributor bearing snap ring (16).