TM 5-3895-379-23
GENERAL WIRING REPAIR - CONTINUED
0108 00
GROUP I TERMINAL ASSEMBLY
1.
Push wire (26) through seal (27) and cavity of con-
nector (25).
26
25
27
401-547
CAUTION
Strip wire after placing it through seal and connector body to prevent damage to individual strands.
2.
Strip end of wire (26) using crimp tool leaving 1/4
26
in. (0.64 cm) of bare wire.
NOTE
When installing terminal be sure termi-
24
nal wings point to the upper jaw of
crimping tool.
3.
Push terminal holder open and insert terminal (24)
until attaching portion of terminal rests on anvil.
CRIMP
TOOL
401-548
0108 00-7