TM 5-3895-379-23-2
0267
DISASSEMBLY
1.
Remove cap (Figure 4, Item 7) from clamp (Figure 4, Item 1) by turning counterclockwise.
2.
Remove screen (Figure 4, Item 5), seal (Figure 4, Item 8), and nozzle (Figure 4, Item 6) from cap
(Figure 4, Item 7).
3.
Remove two screws (Figure 4, Item 2) and clamp (Figure 4, Item 1) from water spray pipe assembly
(Figure 4, Item 4).
4.
Repeat Steps (1) through (3) for remaining clamps as required.
5.
Remove two elbows (Figure 4, Item 3) from water spray pipe assembly (Figure 4, Item 4).
2
1
3
1
8
7
5
4
6
M0232SWR
Figure 4. Water Spray Pipe Disassembly.
END OF TASK
CLEANING AND INSPECTION
1.
Clean screen, seal, nozzle, and clamp with detergent and water. Remove difficult deposits with a stiff bristle
brush.
WARNING
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle
pressure when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when
cleaning components. DO NOT direct compressed air against human skin. Failure to follow
this warning may cause injury or death. Make sure air stream is directed away from user and
other personnel in the area. To prevent injury, user must wear protective goggles or face
shield.
2.
Use a cleaning cloth or compressed air to dry metal parts.
03/15/2011Rel(1.8)root(maintwp)wpno(M00205)