TM 5-3895-379-23-1
0036
MALFUNCTION
Warning Light Relay Faulty.
CORRECTIVE ACTION
1.
Remove warning light relay from operator station (WP 0155).
2.
Set multimeter to measure ohms.
3.
Touch positive (+) probe of multimeter to terminal 85.
4.
Touch negative (-) probe of multimeter to terminal 86 of warning light relay.
5.
Multimeter should measure zero ohms.
6.
Touch positive (+) probe of multimeter to terminal 87A.
7.
Touch negative (-) probe of multimeter to terminal 30 of warning light relay.
8.
Multimeter should measure zero ohms.
9.
Move positive (+) probe of multimeter to terminal 87.
10.
Keep negative (-) probe of multimeter at terminal 30 of warning light relay.
11.
Multimeter should measure infinite ohms.
a.
If multimeter does not measure zero ohms between terminals 85 and 86, replace warning
b.
If multimeter does not measure zero ohms between terminals 30 and 87A, replace warning
c.
If multimeter does not measure infinite ohms between terminals 30 and 87, replace warning
d.
If all continuity checks are OK, go to next malfunction.
PANEL
SCREW
ASSEMBLY
WASHER
SCREW
WASHER
2
RELAY
3
1
4
HARNESS
CONNECTOR
5
OPERATOR
FUNCTIONAL
STATION
LIGHT RELAY
T0183SWR
Figure 9. Warning Light Relay Wiring.