TM 5-3895-379-10
TROUBLESHOOTING PROCEDURES - CONTINUED
0010 00
Table 1. Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ELECTRICAL SYSTEM - CONTINUED
12. Roller Has No Electrical Power - Continued.
BUTTON
401-090
a. If fuse filament is broken,
3. Turn fuse holder cap to left and
notify
supervisor
for
remove cap and fuse from fuse
replacement. Install fuse and
holder labeled KEY START.
cap in fuse holder.
Inspect fuse for broken
filament.
b. If fuse filament is not broken,
fault is not corrected. Install
fuse and cap in fuse holder and
notify supervisor.
BROKEN FUSE
FILAMENT
401-085
0010 00-28