TM 5-3895-379-10
TROUBLESHOOTING PROCEDURES - CONTINUED
0010 00
Table 1. Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ELECTRICAL SYSTEM - CONTINUED
19. Work Lights and Gauge Lights Do Not
Press lights
circuit
breaker
If work lights and gauge lights
Operate.
button.
still do not operate, fault is not
corrected. Notify supervisor.
CB534B SHOWN
LIGHTS CIRCUIT
BREAKER BUTTON
401-092
a. If fuse filament is broken,
20. Horn Does Not Operate.
Turn
fuse
holder
cap
notify
supervisor
for
counterclockwise and remove
replacement. Install fuse and
cap and fuse from fuse holder
cap in fuse holder.
labeled BACKUP ALARM.
Inspect fuse for broken filament.
b. If fuse filament is not broken,
fault is not corrected. Install
fuse and cap in fuse holder and
notify supervisor.
BROKEN FUSE
FILAMENT
401-085