TM 5-3895-382-10
3-7
Do not crank the engine for more than 30 seconds. Engine start switch needs to be returned to the
OFF position before attempting to crank engine again. Allow the starter to cool for 2 minutes before
cranking again.
Keep engine speed low until engine oil pressure indicator light and horn go off. Stop engine if
indicator light does not go off within 10 seconds. Notify Unit Level Maintenance to perform
troubleshooting before restarting engine.
Failure to keep engine speed low until engine oil pressure indicator light and horn go off can result in
turbocharger damage.
NOTE
The vibration on/off switch turns the vibratory
system on by pressing once or off by pressing
again. There is no way to tell if the vibratory
system is on or off when the engine is not
running and on/off switch is in high or low
position.
(5) Ensure that the vibration on/off switch (6) is
turned off (center position).
(6) Turn engine start switch lever (7) to start (full
right) position to crank the engine. Release the
lever when the engine starts.
(7) Immediately push and hold button (5) and push
throttle control (4) down to low idle position
(near to or fully down) for engine warm-up.
Release button.
Do not turn vibratory system on while
Roller is standing still on a very solid
surface. A loss of steering can be
experienced which could result in injury to
personnel.
(8) When desired low idle is reached, turn
throttle lock (3) to full right to lock
throttle control (4) in position.