TM 5-3895-379-10
TROUBLESHOOTING PROCEDURES - CONTINUED
0010 00
Table 1. Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ENGINE - CONTINUED
5. Engine Misfires or Idles Rough -Continued.
c. If air cleaner secondary
element is clogged, notify
supervisor for replacement.
Install secondary and primary
filter elements and cover and
close two air cleaner housing
latches. Reset air filter service
indicator. Close left-side door
d. If air cleaner elements are not
clogged and fault is not
corrected,
install
filter
elements cover, and close two
air filter housing latches. Go to
Step 2.
SECONDARY
AIR FILTER SERVICE
HOUSING
ELEMENT
INDICATOR
SERVICE
SERVICE
PRIMARY
WHEN
WHEN
ELEMENT
RED
LEVEL IS
AT 22
VIEWING
WINDOW
HOUSING LATCHES
401-084
HOUSING COVER
0010 00-17