TM 5-3895-382-24
Vibrato System Component Location.
(2) Vibratory flushing manifold. (3) Vibratory pump. (4) Hydraulic oil cooler. (6) Hydraulic oil tank.
A portion of the hot oil in the closed-loop system is continually
routed through flushing manifold (2). The manifold ports this
hot oil through the oil cooler and then to the hydraulic oil tank.
This permits fresh oil to enter the system regularly, keeping the
components from over-heating. The flushing manifold has
seven test ports which are used to check hydraulic pressure of
the machine systems. Two of the test ports are used for
checking the high/low amplitude pressure settings of the
vibratory system.
13-5