TM 5-3895-379-23
WATER SPRAY TUBES AND FITTINGS REPLACEMENT - CONTINUED
0159 00
TYPE 1 FITTING REPLACEMENT- CONTINUED
5.
Install nut (1) on water line (3).
6.
Install bushing (4) on water line (3).
7.
Install tube (5) in fitting (2).
5
8.
Install water line (3) on tube (5) and in fitting (2).
9.
Tighten nut (1) to fitting (2).
1
3
2
4
401-786
TYPE 2 CLAMP REPLACEMENT
1.
Loosen clamp (1).
1
2.
Remove clamp (1) and water line (2) from fitting (3).
Discard clamp if damaged.
3
2
401-787
3.
Install clamp (1) on water line (2).
4.
Position water line (2) on fitting (3) and tighten clamp (1).
0159 00-2