TM 5-3895-379-23
HYDRAULIC OIL CAP ASSEMBLY MAINTENANCE - CONTINUED
0146 00
CLEANING AND INSPECTION - CONTINUED
WARNING
Cleaning compound, solvent MIL-PRF-680 Type III is an environmentally compliant and low toxic
material. However, it may be irritating to the eyes and skin. The use of protective gloves and goggles is
suggested. Use in well-ventilated areas. Keep away from open flames and other sources of ignition.
2.
Clean all metal parts with cleaning compound, solvent.
3.
Use cleaning cloth or compressed air to dry all metal parts.
4.
Check cap (11) and cover (9) for nicks, cracks, dents and stripped threads. Replace all damaged parts.
INSTALLATION
1.
Install lever (3) on cover (9) with pin (13).
WARNING
Retaining ring is under spring tension to avoid injury, wear eye protection and use caution when installing.
2.
Install ball (12), cap (11) and retaining ring (10) in cover (9).
3.
Install pressure plate (8) and new gasket (7) in cover (9).
0146 00-3