TM 5-3895-379-23
MAIN RELAY REPLACEMENT - CONTINUED
0067 00
REMOVAL - CONTINUED
4.
Disconnect main relay connector (6) from connector (7).
NOTE
Tag and mark all wires prior to removal.
5.
Remove two nuts (8) and two wires (9) and (10) from main relay (11).
6.
Remove two locknuts (12), washers (13) and main relay (11) from operator station (3). Discard locknuts.
10
9
8
12
13
11
7
3
6
401-445
INSTALLATION
1.
Install main relay (11) on operator station (3) with two washers (13) and new locknuts (12). Tighten locknuts.
2.
Install two wires (9) and (10) on main relay (11) with two nuts (8).
3.
Connect main relay connector (6) with connector (7).
0067 00-2