WARNING
Cleaning compound, solvent MIL-PRF-680 Type III is an environmentally compliant and low toxic
material. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames and other sources of ignition.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when cleaning compo-
nents. DO NOT direct compressed air against human skin. Failure to follow this warning may result in
injury or death. Make sure air stream is directed away from user and other personnel in the area. To pre-
vent injury, user must wear protective goggles or face shield.
20.
Clean sediment bowl (7) and screen (8) with solvent cleaning compound.
21.
Wipe strainer assembly (10) clean with rag. If any component is damaged, notify supervisor to obtain replacement.
22.
Install new O-ring (8), screen (9) and sediment bowl (7) on strainer assembly (10).
7
9
10
8
CLOSE
OPEN
ON CB534B
ONLY
CLOSE
OPEN
401-115
0024 00-7