TM 5-3895-379-10
TROUBLESHOOTING PROCEDURES - CONTINUED
0010 00
Table 1. Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
WATER SPRAY SYSTEM - CONTINUED
a. If water tank shutoff valve is
39. Spray Occurs On One Drum Only -
2. On CB534B, check that the
not open, open valve.
Continued.
water tank shutoff valve at the
non-operating tank is open.
Valve handle will be in-line
with the valve when the valve
is open.
b. If water tank shutoff valve is
open, go to Step 3.
WATER TANK
SHUTOFF VALVE
WATER
LEVEL GAUGE
CLOSED
OPEN
FRONT SIDE SHOWN
REAR SIDE SIMILAR
PLATE SHOWN
REMOVED FOR
CLARITY
401-094
3. Check for pinched or damaged
a. If water line(s) is pinched or
water lines.
damaged, component is faulty.
Notify supervisor.
b. If water lines are not pinched
or damaged, fault is not
corrected. Notify supervisor.
0010 00-41