TM 5-3895-379-10
OPERATION UNDER USUAL CONDITIONS - CONTINUED
0005 00
OPERATE WATER SPRAY SYSTEM - CONTINUED
3.
Override Failed Water Spray System Pump.
NOTE
Water spray system consists of two identical but separate systems located at each end of the roller. If
pump of one system fails, operator can open the tie-line valve to supply water flow to both systems.
For the CB534C Roller, use switches on operator console to select proper pump and tank for use. Refer
a.
Lift latch (3), pull handle (4) toward front of roller (5) and open right-side door assembly (6).
b.
Unhook lanyard (7) from door assembly (6) and hook lanyard to frame assembly (8).
c.
Turn tie-line valve (9) to OPEN position.
d.
Unhook lanyard (7) from frame assembly (8) and hook lanyard to door assembly (6).
e.
Close right-side door assembly (6), push handle (4) into latch (3) and close latch.
8
7
6
6
3
5
4
OPEN
CLOSED
9
401-047